+86-512-6665-2225 ext. 8151 sales@donglingtech.com
PRODUCT SERVICE

感应式电动振动试验系列

CONTROL SYSTEM

  • Amber Vibration Controller

    Induction Electro-dynamic Vibration Test System



    Inductive electro-dynamic vibration test system mainly used to do high level and long time reliability vibration test of the products, induction shaker utilize the couple mode of transformer, the coil is fixed on the inner and outer magnets, though the AC drive current, the coil induct the armature, thus making vibration.

    Performance Characteristics

    • Maximum sine acceleration:200g

    • Maximum random acceleration: Above 100g

    • maximum shock acceleration: 600g

    • 25kN~200kN shock force 25KN~200KN

    • 65mm maximum displacement 65mmm

    System modelIES-25-240IES-45-340IES-70-445
    hole pattern of armature东菱东菱东菱
    Sine peak(kgf)250045007000
    Max. displacement (Sine , Shock) p~p(mm)*205151
    Frequency range (Hz)5-50002-40002-2500
    Max. acceleration(g)130125140
    Random Max. acceleration(g)*100100100
    Max. velocity (Sine m/s)*222
    Max. velocity (Shock m/s)*3.63.63.6
    First Resonance Frequency(Hz)280028002300
    Anti-overturning moment(Nm)>400>500>10000
    Mass of moving elements(kg)+183550
    armature diameter(mm)02400)3400445
    Cooling typeAir cooled + spray cooledAir cooled + spray cooledAir cooled + spray cooled
    Max. load(kg)150500800
    Flux leakage(mT)<1<1<1
    Dimension(L×W×H:mm)1336x860x11781328X854X11401605x1130x1375
    Weight(kg)100030004500

    Power amplifier modelIDA60IDA-100IDA-140
    Max. powerkVA)60100140
    signal to noise ratio(dB)彡70>70>70
    output voltage(Vrms)300300300
    Power amplifier efficiency彡92%彡92%彡92%
    system protectionMultiple protectionMultiple protectionMultiple protection
    Dimension(L×W×H:mm)550x800x20701800X1010X20201800X1010X2020
    Weight(kg)300550600

    Blower modelB7000AB-7000B-7000
    Blower efficiency(kW)223030
    Air flow(m3/s)1.361.61.6
    Air pressure(kPa)0.0877.57.5
    air duct diameter(mm)200200200
    Weight(kg)400340340

    System working environmentIES-25-240IES-45-340IES-60-445
    Temperature(。C)0-400-400-40
    Humidity0-90%, no condensation0-90%,no condensation0-90%,no condensation
    power supply3 phrase Ac,380V±10%,3 phrase Ac,380V±10%,3 phrase Ac,380V±10%,
    50Hz,80kVA50Hz,130kVA50Hz,200kVA
    compressed air requirement(Mpa)0.60.60.6
    water requirementWaterWaterWater

    optional accessories Slip table, Head expander, Movable device, Thermal barrier, Climate chamber, Fixture, Sensor, Vibration Controller,Power amplifier remote control Note:* is optional
    System modelIES-100 I 120-445IES-160 I 200-650
    hole pattern of armaturedonglingdongling
    Sine peak(kgf)10000/1200016000 1 20000
    Max. displacement Sinep〜p (m m) ★51 (可选76)76
    Max. displacement Shock p〜p(mm)*51 (可选76)76
    Frequency range (Hz)2-22002-2000
    Max. acceleration(g)150/180140 1 160
    Random Max. acceleration(g)*110/130100
    Max. velocity (Sine m/s)*21.8/2
    Max. velocity (Shock m/s)*3.6/53.6/5
    First Resonance Frequency(Hz)21001800
    Anti-overturning moment(Nm)>10000>14000
    Mass of moving elements(kg)+60115
    armature diameter(mm)(D4450)650
    Cooling typeAir cooled + spray cooledAir cooled + Water cooled+ Spray cooled
    Max. load(kg)6001200
    Flux leakage(mT)<1<1
    Dimension(L×W×H:mm)1590x1223x13751605x1124x1342
    Weight(kg)600010000

    Power amplifier modelIDA-240 | 300IDA360 | 480
    Max. powerkVA)240/300360/480
    signal to noise ratio(dB)>10>65
    output voltage(Vrms)300300
    Power amplifier efficiency彡92%彡92%
    system protectionMultiple protectionMultiple protection
    Dimension(L×W×H:mm)1800X1010X2020 1 2400X1010X20203000X1010X2020
    Weight(kg)1200 1 15001800 1 1900

    Blower modelB-7000B-7000
    Blower efficiency(kW)3030
    Air flow(m3/s)1.61.6
    Air pressure(kPa)7.57.5
    air duct diameter(mm)200200
    Weight(kg)340340

    cooling unitCU-1CU-2
    Internal circle water flow(distilled water)(L/min)4580
    Internal water pressure(distilled water)(Mpa)11
    External circle water flow(city water) (L/m i n)100200
    External water pressure(city water)(Mpa)0. 25-0. 40. 25-0. 4
    Distilled water requirementHardness 30ppm, PH7-8, conductivity 1µS/cmHardness 30ppm, PH7-8, conductivity 1µS/cm
    power requirement(kVA)88
    Weight(kg)630750

    cooling unitSystem working environmentSystem working environment
    Temperature(。C)0-400-40
    Humidity0-90%,no condensation0-90%,no condensation
    compressed air requirement(Mpa)0.60.6
    power supplyAC 3 phrase Ac,380V±10%,50Hz,280/320kVAAC 3 phrase Ac,380V±10%,50Hz,420/480kVA
    optional accessories•Slip table, Head expander, Movable device, Thermal barrier, Climate chamber, Fixture, Sensor, Vibration Controller,Power amplifier remote control